|
產(chǎn)品展示
網(wǎng)站首頁(yè) > 產(chǎn)品中心
|
SPIDER II 8TX EEC赫斯曼工業(yè)交換機(jī)入門級(jí)
產(chǎn)品編號(hào):201791219213
產(chǎn)品價(jià)格:¥
產(chǎn)品描述:SPIDER II 8TX EEC赫斯曼工業(yè)交換機(jī)入門級(jí)
|
|
產(chǎn)品介紹
Product description
Description |
Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s) |
Port type and quantity |
8 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity |
Type |
SPIDER II 8TX EEC |
Order No. |
943 958-001 |
More Interfaces
Power supply/signaling contact |
1 plug-in terminal block, 3-pin, no signaling contact |
Network size - length of cable
Twisted pair (TP) |
0 - 100 m |
Multimode fiber (MM) 50/125 μm |
n/a |
Multimode fiber (MM) 62.5/125 μm |
n/a |
Single mode fiber (SM) 9/125 μm |
n.v. |
Single mode fiber (LH) 9/125 μm (long haul transceiver) |
n.v. |
Network size - cascadibility
Line - / star topology |
Any |
Power requirements
Operating voltage |
DC 9.6 V - 32 V |
Current consumption at 24 V DC |
max. 235 mA |
Power consumption |
max. 5.8 W; 19.8 Btu(IT)/h |
Service
Diagnostics |
LEDs (power, link status, data, data rate) |
Redundancy
Ambient conditions
Operating temperature |
-40 oC to +70 oC |
Storage/transport temperature |
-40 oC to +85 oC |
Relative humidity (non-condensing) |
10% to 95% |
MTBF |
1,239,618 hours; Telcordia SR-332; Gb 25oC |
Mechanical construction
Dimensions (W x H x D) |
35 mm x 138mm x 121 mm |
Mounting |
DIN Rail 35 mm |
Weight |
246 g |
Protection class |
IP 30 |
Mechanical stability
IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
IEC 60068-2-6 vibration |
3,5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) |
6 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field |
10 V/m (80 - 1000 MHz) |
EN 61000-4-4 fast transients (burst) |
2 kV power line, 4 kV data line |
EN 61000-4-5 surge voltage |
power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line |
EN 61000-4-6 conducted immunity |
10 V (150 kHz - 80 kHz) |
EMC emitted immunity
FCC CFR47 Part 15 |
FCC CFR47 Part 15 Class A |
EN 55022 |
EN 55022 Class A |
Approvals
Safety of industrial control equipment |
cUL 508 |
EMV regulations for assembly in vehicles |
n/a |
Employment in vehicles |
E1 |
Scope of delivery and accessories
Scope of delivery |
Device, terminal block, operating manual |
Accessories to order separately |
Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame |
|